Description
The temperature sensor made of platinum wire as the temperature sensing element is abbreviated as the wire wound platinum wire temperature sensor. It has the same purpose as the temperature sensor made of platinum film resistance as the temperature sensing element, and can also be used for motor winding temperature measurement, motor slot temperature measurement, shaft end temperature measurement, etc.
Technical parameters
Temperature measuring element | Wire wound platinum resistorPt100(IEC 60751) |
Thermosensitive zone:55*7*0.5mm | |
Tolerance | Grade B or ± 0.5% (0 ℃) |
Working current | ≦5mA |
Electromagnetic compatibility | IEC 62236-3-2 |
Insulation | ≥500MΩ @500Vac/50Hz/60S |
Insulation probe temperature measurement working range | -50℃~250℃ |
Vibration resistance | 300m/s2(IEC 61373 cat3.) |
Impact resistance | 1000m/s2(IEC 61373 cat3.) |
Protection grade | IP68 |
Sketch Map
Note: Temperature transfer products made of wire wound temperature sensing components have a minimum size limit. The temperature transfer size between slots: length * width * thickness (Lb * W * t) should not be less than 80mm * 10mm * 3mm, and the thickness size usually depends on the outer diameter of the selected lead wire
Ordering Example
Note
1. During installation, protect the sensor lead out cable and strictly prohibit forceful pulling;
2. During the AC voltage withstand test of the motor, the sensor wire should be short circuited to ground, and the shielding wire should be grounded;
3.After the installation and connection of the sensor are completed, it is necessary to verify whether the wiring is correct and confirm before proceeding
Power transmission to avoid damage caused by strong electricity mistakenly connecting to sensors;
4. When the storage period of the sensor exceeds 1 year, the temperature resistance value and insulation resistance value of the sensor should be tested before installation to ensure good sensor performance;
Description
The temperature sensor made of platinum wire as the temperature sensing element is abbreviated as the wire wound platinum wire temperature sensor. It has the same purpose as the temperature sensor made of platinum film resistance as the temperature sensing element, and can also be used for motor winding temperature measurement, motor slot temperature measurement, shaft end temperature measurement, etc.
Technical parameters
Temperature measuring element | Wire wound platinum resistorPt100(IEC 60751) |
Thermosensitive zone:55*7*0.5mm | |
Tolerance | Grade B or ± 0.5% (0 ℃) |
Working current | ≦5mA |
Electromagnetic compatibility | IEC 62236-3-2 |
Insulation | ≥500MΩ @500Vac/50Hz/60S |
Insulation probe temperature measurement working range | -50℃~250℃ |
Vibration resistance | 300m/s2(IEC 61373 cat3.) |
Impact resistance | 1000m/s2(IEC 61373 cat3.) |
Protection grade | IP68 |
Sketch Map
Note: Temperature transfer products made of wire wound temperature sensing components have a minimum size limit. The temperature transfer size between slots: length * width * thickness (Lb * W * t) should not be less than 80mm * 10mm * 3mm, and the thickness size usually depends on the outer diameter of the selected lead wire
Ordering Example
Note
1. During installation, protect the sensor lead out cable and strictly prohibit forceful pulling;
2. During the AC voltage withstand test of the motor, the sensor wire should be short circuited to ground, and the shielding wire should be grounded;
3.After the installation and connection of the sensor are completed, it is necessary to verify whether the wiring is correct and confirm before proceeding
Power transmission to avoid damage caused by strong electricity mistakenly connecting to sensors;
4. When the storage period of the sensor exceeds 1 year, the temperature resistance value and insulation resistance value of the sensor should be tested before installation to ensure good sensor performance;